Pressure Transmitters...
The differential pressure switch has a synthetic spring suspended membrane which is linked to a changeover contact. When the differential pressure exceeds the setpoint value the contact changes. The differential pressure switch is used to supervise and monitor fans, filters and air handling units, to control defrosting functions etc.
Regin pressure and differential pressure transmitters use a ceramic measuring beam. The differential pressure affects a membrane taht works directly against the measuring beam with film resistor. When the resistance changes it is converted to a proportional output control signal.
• High degree of accuracy • Few moving parts - rapid response • Excellent long-term stability
The air velocity sensor operates with a specially designed thin-film element which is heat (the hot-film anemometer principle). The cooling rate of the element, which depends on the air velocity, is measured and transformed to an output signal proportional to the air speed.
• Stable output signal compensated for varying temperature • Extremely high frequency response. Not sensitive to contamination by dust etc.
The flow switch operated by an electrical blade-type tripping device interrupts the electric control circuit of the boiler/chiller when there is insufficient water circulation in the boiler/chillerpipe owing to some abnormal condition. ---------------------------------------------------------------------------------- DIFFERENTIAL PRESSURE SWITCH DTV
|
Switch DTV Media: Air and non-corrosive gases Max. overload pressure: 5000 Pa Relay contact data: 5A (0,8 A) 250 V AC Ambient temperature: -20...+85°C Protection class: IP54
DTV200: 20...300 Pa DTV500: 50...500 Pa DTV1000: 100...1000 Pa DTV2000: 500...2000 Pa DTV5000: 1000...5000 Pa |
 | ---------------------------------------------------------------------------------- DIFFERENTIAL PRESSURE TRANSMITTER WITH DISPLAY FOR AIR DMD
|
Transmitter DMD Supply voltage: 24 V AC or DC, 5 VA Output: 0...10 V DC or 4...20mA, selectable Working range: 0...100Pa, 0...300Pa, 0...500Pa, 0...1000Pa, selectable Accuracy: +/- 1% at 20°C Electronic damping: 0...20s Display: LED, 3 digits Protection class: IP54
DMD- transmitter with display DMD-LON - transmitter with display and LonWorks |
 | ---------------------------------------------------------------------------------- DIFFERENTIAL PRESSURE TRANSMITTER FOR AIR AND NON-CORROSIVE GASES DTL
|
Transmitter DTL Supply voltage: 24 V AC (24 V DC, 2-wire for 4...20mA) 0,24 VA Accuracy: +/-1% fs Ambient temperature: 0...70°C Protection class: IP65
DTL5/05: -50...+50 Pa; 0...10 V DC DTL5/05-420: -50...+50 Pa; 4...20 mA DTL1: 0...100 Pa; 0...10 V DC DTL1-420: 0...100 Pa; 4...20 mA DTL3: 0...300 Pa; 0...10 V DC DTL3-420: 0...300 Pa; 4...20 mA DTL5: 0...500 Pa; 0...10 V DC DTL5-420: 0...500 Pa; 4...20 mA DTL10: 0...1000 Pa; 0...10 V DC DTL10-420: 0...1000 Pa; 4...20 mA DTL16: 0...1600 Pa; 0...10 V DC DTL16-420: 0...1600 Pa; 4...20 mA DTL25: 0...2500 Pa; 0...10 V DC DTL25-420: 0...2500 Pa; 4...20 mA DTL50: 0...5000 Pa; 0...10 V DC DTL50-420: 0...5000 Pa; 4...20 mA |
 | ---------------------------------------------------------------------------------- DIFFERENTIAL PRESSURE TRANSMITTER FOR LIQUIDS AND NON-CORROSIVE GASES DTK
|
Transmitter DTK Supply voltage: 24 V AC/18...33 V DC (output 0...10 V DC) 0,1 VA 11...33 V DC, 2-wire (output 4...20 mA) 0,5 VA Output : 0...10 V DC ar 4...20 mA (2-wire) Accuracy: +/-1,3% fs (DTK10...DTK250) +/-0,8% fs (DTK400), +/-0,5% fs (DTK600...DTK2500) Ambient temperature: -15...+80°C Connection: Screw fitting for pipe Ø 6 mm included Protection class: IP65
DTK10: 0...10 kPa; 0...10 V DC, 60 kPa DTK10-420: 0...10 kPa; 4...20 mA, 60 kPa DTK20: 0...20 kPa; 0...10 V DC, 120 kPa DTK20-420: 0...20 kPa; 4...20 mA, 120 kPa DTK40: 0...40 kPa; 0...10 V DC, 200 kPa DTK40-420: 0...40 kPa; 4...20 mA, 200 kPa DTK100: 0...100 kPa; 0...10 V DC, 500 kPa DTK100-420: 0...100 kPa; 4...20 mA, 500 kPa DTK250: 0...250 kPa; 0...10 V DC, 1200 kPa DTK250-420: 0...250 kPa; 4...20 mA, 1200 kPa DTK400: 0...400 kPa; 0...10 V DC, 1200 kPa DTK400-420: 0...400 kPa; 4...20 mA, 1200 kPa DTK600: 0...600 kPa; 0...10 V DC, 1200 kPa DTK600-420: 0...600 kPa; 4...20 mA, 1200 kPa DTK1000: 0...1000 kPa; 0...10 V DC, 2000 kPa DTK1000-420: 0...1000 kPa; 4...20 mA, 2000 kPa DTK1600: 0...1600 kPa; 0...10 V DC, 3200 kPa DTK1600-420: 0...1600 kPa; 4...20 mA, 3200 kPa DTK2500: 0...2500 kPa; 0...10 V DC, 5000 kPa DTK2500-420: 0...2500 kPa; 4...20 mA, 5000 kPa |
 | ---------------------------------------------------------------------------------- PRESSURE TRANSMITTER FOR LIQUIDS AND GASES TTK
|
Transmitter TTK Supply voltage: 24 V AC/18...33 V DC (output 0...10 V DC) 0,1 VA 11...33 V DC, 2-wire (output 4...20 mA) 0,5 VA Output: 0...10 V DC or 4...20 mA (2-wire) Accuracy: +/-0,3% Ambient temperature: -15...+80°C Connection: R1/4" Protection class: IP65
TTK1: 0...100 kPa; 0...10 V DC TTK1-420: 0...100 kPa; 4...20 mA TTK2: 0...200 kPa; 0...10 V DC TTK2-420: 0...200 kPa; 4...20 mA TTK5: 0...500 kPa; 0...10 V DC TTK5-420: 0...500 kPa; 4...20 mA TTK10: 0...1000 kPa; 0...10 V DC TTK10-420: 0...1000 kPa; 4...20 mA TTK16: 0...1600 kPa; 0...10 V DC TTK16-420: 0...1600 kPa; 4...20 mA TTK25: 0...2500 kPa; 0...10 V DC TTK25-420: 0...2500 kPa; 4...20 mA TTK40: 0...4000 kPa; 0...10 V DC TTK40-420: 0...4000 kPa; 4...20 mA TTK100: 0...10 MPa; 0...10 V DC TTK100-420: 0...10 MPa; 4...20 mA |
 | ---------------------------------------------------------------------------------- AIR VELOCITY TRANSMITTER AVDT25
|
Transmitter AVDT25 Supply voltage: 24 V AC +/-20%, 4 VA Working range: 0...10m/s, 0...15m/s, 0...20 m/s Output: 0...10 V (Max. 1mA) 4...20mA Time constant: 1,5 s at 10 m/s Accuracy: +/- (0,3 m/s +3% of value), at 0...10 m/s +/- (0,3 m/s +3% of value), at 10...15 m/s +/- (0,3 m/s +4% of value), at 0...20 m/s Damping: 0,2 or 2 s (optional) Ambient temperature: -10...+50°C Insertion length: 50...200 mm, adjustable Mounting: Duct-mounting Protection class: IP54 |
 | ---------------------------------------------------------------------------------- FLOW SWITCH FLS304
|
Switch FLS304 Contact data: 6 (2) A, 250 V AC, change-over contact Max . fluid pressure: 10 bar, tested to 15 bar Max. fluid temperature: 110°C Storage temperature: -20...+80°C Protection class: IP64 |
 | ---------------------------------------------------------------------------------- Ever Yours NIT
|