Pressure Transmitters...
The differential pressure switch has a synthetic spring suspended membrane which is linked to a changeover contact. When the differential pressure exceeds the setpoint value the contact changes. The differential pressure switch is used to supervise and monitor fans, filters and air handling units, to control defrosting functions etc.
Regin pressure and differential pressure transmitters use a ceramic measuring beam. The differential pressure affects a membrane taht works directly against the measuring beam with film resistor. When the resistance changes it is converted to a proportional output control signal.
• High degree of accuracy • Few moving parts - rapid response • Excellent long-term stability
The air velocity sensor operates with a specially designed thin-film element which is heat (the hot-film anemometer principle). The cooling rate of the element, which depends on the air velocity, is measured and transformed to an output signal proportional to the air speed.
• Stable output signal compensated for varying temperature • Extremely high frequency response. Not sensitive to contamination by dust etc.
The flow switch operated by an electrical blade-type tripping device interrupts the electric control circuit of the boiler/chiller when there is insufficient water circulation in the boiler/chillerpipe owing to some abnormal condition. ---------------------------------------------------------------------------------- DIFFERENTIAL PRESSURE SWITCH DTV
|
Switch DTV Media: Air and non-corrosive gases Max. overload pressure: 5000 Pa Relay contact data: 5A (0,8 A) 250 V AC Ambient temperature: -20...+85°C Protection class: IP54
More > DTV.pdf |
 | ---------------------------------------------------------------------------------- DIFFERENTIAL PRESSURE TRANSMITTER WITH DISPLAY FOR AIR DMD
|
Transmitter DMD Supply voltage: 24 V AC or DC, 5 VA Output: 0...10 V DC or 4...20mA, selectable Electronic damping: 0...20s Display: LED, 3 digits Protection class: IP54
More > DMD.pdf |
 | ---------------------------------------------------------------------------------- DIFFERENTIAL PRESSURE TRANSMITTER FOR AIR AND NON-CORROSIVE GASES DTL
|
Transmitter DTL Supply voltage: 24 V AC (24 V DC, 2-wire for 4...20mA) 0,24 VA Ambient temperature: 0...70°C Protection class: IP65
More > DTL.pdf |
 | ---------------------------------------------------------------------------------- DIFFERENTIAL PRESSURE TRANSMITTER FOR LIQUIDS AND NON-CORROSIVE GASES DTK
|
Transmitter DTK Supply voltage: 24 V AC/18...33 V DC (output 0...10 V DC) 0,1 VA 11...33 V DC, 2-wire (output 4...20 mA) 0,5 VA Output : 0...10 V DC ar 4...20 mA (2-wire) Ambient temperature: -15...+80°C Protection class: IP65
More > DTK.pdf |
 | ---------------------------------------------------------------------------------- PRESSURE TRANSMITTER FOR LIQUIDS AND GASES TTK
|
Transmitter TTK Supply voltage: 24 V AC/18...33 V DC (output 0...10 V DC) 0,1 VA 11...33 V DC, 2-wire (output 4...20 mA) 0,5 VA Output: 0...10 V DC or 4...20 mA (2-wire) Ambient temperature: -15...+80°C Protection class: IP65
More > TTK.pdf |
 | ---------------------------------------------------------------------------------- AIR VELOCITY TRANSMITTER AVDT25
|
Transmitter AVDT25 Supply voltage: 24 V AC +/-20%, 4 VA Output: 0...10 V (Max. 1mA) 4...20mA Time constant: 1,5 s at 10 m/s Ambient temperature: -10...+50°C Insertion length: 50...200 mm, adjustable Mounting: Duct-mounting Protection class: IP54
More > AVDT25.pdf |
 | ---------------------------------------------------------------------------------- FLOW SWITCH FLS304
|
Switch FLS304 Contact data: 6 (2) A, 250 V AC, change-over contact Max . fluid pressure: 10 bar, tested to 15 bar Max. fluid temperature: 110°C Storage temperature: -20...+80°C Protection class: IP64
More > FLS034.pdf |
 | ---------------------------------------------------------------------------------- Ever Yours NIT
|